Product Info

Power supply SPD

 
Power supply SPD  

These are SPD (surge protective device) that comply with IEC standards for direct lightning surge 10/350μs, and induction lightning surge 8/20μs. These direct lightning protective products have the same kind of lightning protection performance that is required of protection level I (direct lightning surge 200kA), and are high performance devices that can be easily installed in areas that are prone to lightning strikes.

We have a range of devices to protect against induction lightning, depending on the circuit configuration. We can also supply element type devices.




 

Class I SPD (resistant to direct lightning surge)

 

MZS-200AV  series

 

MZG-200  series

 

MZS-400AV  series






MZS-200AV  series   MZG-200  series   MZS-400AV  series





Resistant to direct lightning surge

These are SPD (surge protective device) for Class I and II that will protect power supply circuits of up to AC230V from lightning surges.

They are equipped with Device deterioration facilitys and warning contact outputs.

 

Resistant to direct lightning surge

These are SPD (surge protective device) for Class I and II that will protect power supply circuits of up to AC230V from lightning surges.

They are a high withstand capacity type, resisting impulse current up to Iimp 50kA.

 

 Resistant to direct lightning surge

These are SPD (surge protective device) for Class I and II that will protect power supply circuits of up to AC460V from lightning surges. They are equipped with Device deterioration facilitys and warning contact outputs.

     

 

Class II SPD (resistant to induction lightning surge)

 

Smart SPD

System 

 

Smart SPD

SMB-MZSR200/400type

 

MZSR-200/400type

 






Smart SPD System   SMB-MZSR200/400type   MZSR-200/400type





Smart SPD series
IEC Class II compliant

“Smart SPD series” have a replacement recommendation display function based on lightning surge measurements. They are IEC Class II compliant SPDs which can protect power supply circuits from lightning surge. By using with a monitor unit, they can also check lightning surge information and the condition of SPDs, and be monitored via LAN.

 

Smart SPD series
IEC Class II compliant

“Smart SPD series” have a replacement recommendation display function based on lightning surge measurements. They are IEC Class II compliant SPDs which can protect power supply circuits from lightning surge. They are plug-in type so the jack can be taken off from the body. They also have a replacement recommendation display function, a lightning surge count display function and a deterioration display function with a warning contact output.

 

IEC Class II compliant


They are IEC Class II compliant SPDs which can protect power supply circuits from lightning surge. They are plug-in type so the jack can be taken off from the body and have a deterioration display function with a warning contact output.

 

PMZtype

 

MKY, MKYS series

 

MZCR-100/200/400type






pmz type   MKY, MKYS series   MZCR-400type





IEC Class II compliant


They are IEC Class II compliant SPDs which can protect power supply circuits up to AC275V from lightning surge.
They are space saving design to be put inside devices and boards, and a single unit can provide protection across lines and grounds. They have a deterioration and defect display function by LED, and also a built-in isolation function to prevent overheating in the event of deterioration.

 

IEC Class Ⅱ, 61643-1/IEC 62305-4 Compliant

Power supply Class ⅡSPD to protect power circuits for AC100V/ 200V/400V from lightning surge. Width is 50mm/75mm with deterioration display and alarm output.

 

Resistant to induction lightning surge

This is a Class II SPD (surge protective device) for the protection of power supply circuits up to AC500V from lightning surges. The device is a plug in type that allows the jack and main unit to be separated. The device is also equipped with a deterioration display and warning contact output.

 

MZCRW-200JK1type

 

MZE-100/200type

 

FV-100/200/400 type






MZCRW-200JK1type   MZE-100/200type   FV-100/200/400 type





Maximum discharge current 80kA
Resistant to induction lightning surge

This is a Class II SPD (surge protective device) for the protection of power supply circuits up to AC255V from lightning surges. The device is a plug in type that allows the jack and main unit to be separated. The device is also equipped with a deterioration display and warning contact output.

 

Resistant to induction lightning surge


This is a Class II SPD (surge protective device) offering lightning surge protection for AC110V/230V power supply circuits. Equipped with an LED Device deterioration facility, one device can service a 2-wire single phase system.

 

IEC Class II compliant



It protects power supply circuits up to AC130V/230V/460V from lightning surge. It is plug-in type that allows the jack and main unit be separated. Deterioration display function mounted.

 

Other power supply protective devices

 

AV11, AV13, AV14 type

 

AV3P1 type, AV3P-1 type, AV3P-2 type

   





AV-11, AV-13, AV-14 type   AV3P-1 type, AV3P-2 type    





These power supply protective devices provide lightning surge protection for power supply circuits of up to AC 125V, 240C, and 440V.

These are element type devices that can be mounted on PCBs and are useful in space-limited installation.

UL approved
RoHS compliant

 

These are compact, three electrode type power supply protective devices that provide lightning surge protection for power supply circuits of up to AC 125V, 240C, and 440V.

These are element type devices that can be mounted on PCBs and are useful in space-limited installation.

UL approved(AV3P1 type)
RoHS compliant

   

 


PAGE TOP